Features & Highlights:
- AMV’s Large and Powerful HDR and 4K Production Truck
- Sony XVS 8000 (UHD/3G/HD Capable) 5 ME W/ Aux Buses that Can Dissolve (Up to 12)
- Sony 4300 Cameras
- Sony HDC-F5500, Sony Venice II, Sony F-55 Live Cameras available optionally upon request
- Wired for 20 Video Recording Machines and 4 EVS Chassis
- 3- 30” OLED 4K Monitors in Production
- Studer Vista X; (Audio Back Bench in Audio Room)
- 32 IN and 32 OUT Single Mode ST Fiber to I/O from Grass Valley Router
- 32 x 32 Dante/ Analog converter I/O Box
- 104 DeEmbedders, 160 Embedders, 16 Frame syncs. MADI 7 In – 8 Out on Router
- 16 XVP Up/Down/Cross Converters w/ 23.98p to 23.98psf
- 59′ Double-Expando
Zurich Truck Specs – View/Download PDF
PRODUCTION:
Sony XVS 8000 (UHD/3G/HD Capable) Switcher, (112 Inputs X 48 Outputs); 5 ME W/ 4 external DME Channels & Re-Sizers on all Keyers; Back Bench/ Screens Switching Panels (2- 25 button X-Point Moduals & 2- Transition/ Flexi Pad Moduals) Attached to Main Switcher Frame; 128 X 8 Multi View Monitor Wall; 48 X 4 External Multi View to I/O.
AUDIO:
- Studer Vista X W/ 72 Faders on the Surface with built in dual PCM96 effects processors
- Studer Stage Boxes W/ SMPTE Fiber (Optional) (2) 48 X 16 & (1) 40 Stage Boxes
- 128 channels of DANTE I/O
- 4 Engine TC Electronics System 6000
- Extensive MADI routing
- 2 Lexicon PCM 96
CAMERAS:
- 12 Sony 4300-4K (Wired for 16)+
- Sony HDC-F5500, Sony Venice II, Sony F-55 Live available optionally upon request
ROUTER/ CONVERSION:
- 104 DeEmbedders, 160 Embedders, 16 Frame syncs. MADI 7 In-8 Out on Router;
- 64X64 AES Router; 64X64 ST Analog Router
- 6 4K Up/Down Converters (Available Upon Request)
- 2 4K Color Corrector Channels Available
- 8 HD Color Corrector Channels Available
RECORD & PLAYBACK:
- Up to 4 8-Channel EVS
- 10 VTR Slots/Wired for 20
- 4 Channel H.264 Recorder
- 6 Time Code Keyers
COMMUNICATIONS:
- RTS Adam M OMNEO Intercom with 208 X 208 Ports
- 8– RTS Tiff 4000s
GRAPHICS:
POWER REQUIREMENTS:
- A-Unit: 1 Service, 200 AMP, 3 Phase, 208 Volts
- B-Unit: 1 Service, 100 AMP, 3 Phase, 208 Volts (Only Required if Used for Production)
SPACE REQUIREMENTS:
- A-Unit: (All Measurements Without Tractor)
56’8” Long x 13’6” High x 8’6” Wide– Closed (W/ the Longest Tractor Length is 77’4”)
59’ Long x 13’6” High x 15’10” Wide– Expanded W/ AC Flaps Open & Stairs Perpendicular to Curb
- B-Unit: (All Measurements Without Tractor)
51’6” Long x 13’6” High x 8’6” Wide– Closed
58’ Long x 13’6” High x 8’6” Wide– W/ Liftgate Down & Side Door Closed
Mobile unit equipment list subject to change without notice. Additional equipment available. Please consult with your AMV Account Executive regarding availability and per-event specifications.